0000012833 00000 n Vulcraft employs the latest technology in manufacturing and fabricating in its quest to . Online design tools that make it easy to find the right product for your next project. Vulcraft Literature startxref Deck Type Unrestrained Beam Rating 1.5VL 2VL 3VL 1.5VLP 2VLP 3VLP (hr.) The PunchLok II System uses a specially designed pneumatic tool to achieve a stronger and more positive attachment than screwed sidelaps or conventional button punches. Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck. CADdetails | Free CAD drawings, 3D BIM models, Revit files and Specs Preparing QuickPack . Steel roof and floor decks have long been recognized for their economy because of their light weight and high strength-to-weight ratio. For best output results, we recommend the following: B Deckprofilesare 1.5-inchdeep structural roof deck that provide both vertical load and diaphragm shear capacity. BIM provides many benefits to the building project and its owners and the demand for BOM information continues to increase. 0000010366 00000 n These profiles are also available with acoustical properties (1.5BPA and 1.5PLBPA). Second to none in service and backed by the Nucor family of quality companies, Vulcraft is destined to be North Americas best one-source for standard, heavy duty, and custom fabricated grating. vulcraft deck cad details - ULisboa 0000076363 00000 n CANADIAN STEEL JOISTS & JOIST GIRDER SYSTEMS, STEEL JOISTS & JOIST GIRDER SYSTEMS (UPDATED TO SJI 45TH ED. Open web-steel joists are an engineered, truss-like construction component used to support loads over short and long spans alike. Our latest catalogues are listed below. PDF Vulcraft Composite & Non-composite Deck Ul Fire Rated Assemblies GRADE 50 STEEL 1.5B ROOF DECKS 1.5B-36 Deck used with Side-lap Screws 1.5BI-36 Deck used with TSWs or BPs 1.5PLB-36 Deck used with PunchLok II System Nominal Dimensions Section Properties Deck WeightBase Metal ThicknessYield Strength Effective Moment of Inertiaat Service Load = (2I e+Ig)/3d Effective Section Modulus at F = 50 ksi Allowable Moment By downloading and using any ARCAT content you agree to the following [ license agreement ]. Were one of the largest private landholders in the United States. 0000049636 00000 n Design steel deck to resist the wall anchorage forces from combined seismic, wind, and gravity loading based on the combined axial and bending strength. Vulcraft has a long history of success in the steel joist and deck industry. 0000077244 00000 n Attached is the link to his website where the latest vibration program can be purchased. 0000010964 00000 n By using this website, you agree to ourPrivacy Policy. Design your Axial-Load Transfer between bays with either an Under-Chord or On-Top Tie-Plate detail. The Ecospan Structural Floor System provides innovative, results-driven building solutions. Vulcraft Roof Decks are designed in accordance with the ANSI/Steel Deck Institute RD-2017. 0000079006 00000 n 0000074240 00000 n Contact us at designtools-survey@nucor.com. Type of Protection Concrete Thickness & Type UL Design No. 0000002600 00000 n 265 CAD Drawings for Category: 06 15 00 - Wood Decking. Interested in how Ecospan compares to other floor systems? The PunchLok II System uses a specially designed pneumatic tool to achieve a stronger and more positive attachment than screwed sidelaps or conventional button punches. By acting as both a ceiling and roof, this versatile product combines the strength of roll formed steel with an aesthetically pleasing bottom plate. Check knife plates for both Top Chord and Bottom Chord Axial Load Transfer. Vulcrafts Non-Composite Deck is used as a foundation for floors, stairways, or mezzanines. CANADIAN INSTITUTE OF STEEL CONSTRUCTION (CISC/ICCA), CANADIAN SHEET STEEL BUILDING INSTITUTE (CSSBI/ICTAB), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). The Vulcraft/Verco Group CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. The 3NP profile comes in 24 and 32 widths. The deck profile configu- ration can also be used to interlock concrete and steel. 0000072921 00000 n 0000035798 00000 n 1 steel fabricator by CWB to W47.1 standard. It also is one of the oldest operating divisions of Nucor Corporation. In addition, we ensure the highest level of quality and structural integrity in our steel joists and girders through a mechanical testing program, including full-scale load tests, at every Vulcraft facility. Its list of benefits include significant strength and capacity at longer spans, highly aesthetic underside for exposed ceilings, and unique and effective hanging solution opportunities. When inserting the details directly into a PAPERSPACE drawing, use a 1:1 scale factor and then plot using a 1:1 scale. The CAD versions of the sheets are compatible with AutoCAD 2000 and newer and have been developed to be easily plotted from the Layout tab(s) at a 1:1 scale. deck type gauge c p t b p t b c t p c p b 24 22 20 19 18 16 p t c b roof indiana nebraska south carolina texas alabama/new york approximate dimensions in inches 1.5b, 1.5bl, 1.5ba, 1.5bia . Vulcraft Literature They were created at a 1:1 scale with a 3/32 text height and use colors 30 and 134. Vulcraft/Verco Group CAD Steel Joist Framing | ARCAT The model can be exported containing Vulcraft joist information, which can then be used by Vulcraft to aid in the quoting and detailing process. Our 32 wide N deck adds an extra eight inches to the width of the deck, which translates to greater coverage per sheet, reducing the numbers of sheets that have to be laid. 0000318002 00000 n LEARN MORE ABOUT STEEL JOISTS & JOIST GIRDERS. Tool provides specification guidance, estimated dead loads, stud quantities, bridging, and maximum sizes for ductwork. 0000012748 00000 n N Deck profiles have 3-inch deep ribs making them ideal for span conditions greater than 10 feet or when a specific aesthetic look is desired. Vulcraft designs and manufactures its steel deck in accordance with the specifications of the Steel Deck Institute. Satisfying Code for Fire Protection Requirements, Trus Joist Floor Installation Video Guide, Fire-Rated Assemblies and Sprinkler Systems Guide, When inserting the details into a MODELSPACE drawing, use a scale factor equal to your intended plot scale (e.g., use a 48 scale factor when plotting to a 1/4=1 scale). CANADIAN INSTITUTE OF STEEL CONSTRUCTION (CISC/ICCA), CANADIAN SHEET STEEL BUILDING INSTITUTE (CSSBI/ICTAB), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). N Deck is strong, light weight, economical, and easy to install. Steel members are designed per the latest edition of CAN/CSA S-16. All rights reserved. We're focused on climate change solutions, creating sustainable homes for everyone, and supporting thriving rural communities. Analyze a Composite Joists System for your Floor. Building on its long history of success in the steel joist and deck industry, Vulcraft is well positioned to estimate, detail, custom fabricate, and deliver superior steel bar grating in virtually any configuration. Curving increases panel strength, allows use of lighter-gauge decking for added savings. Vulcraft Home 0000068628 00000 n Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck. 3974 0 obj <>stream For custom design information, please visit our Online Design Tools. Calculate your deck-slab diaphragm strength and stiffness for selected deck profiles based on AISI S310-16. ARCAT | Free Building Product CAD Drawings, BIM, Specs and more If you wish to order a hardcopy, check the box next to each catalog you wish to receive (if available), then simply fill out the contact form provided. 0000012389 00000 n Their dimensions, in inches, apply to the side of the square or the diameter of the round. 0000054279 00000 n CSI Divisions Building Product Categories Certifications Data Sheets Catalog/Vids Catalogs / Videos. They provide a durable and attractive roof or floor system for fast all-weather construction, and they offer excellent lateral diaphragm action thus reducing the necessity for structural bracing. Downloads for Vulcraft/Verco Group, Catalog files (ref: Q:revit Decking family, 0) | ARCAT Vulcraft/Verco Group > e-Catalogs Vulcraft/Verco Group Catalogs / Brochures ARCAT Free catalogs featuring manufacturers products and materials. 1.3C Non-Composite Deck measures 1 5/16-inches in depth; 1.5C Non-Composite Deck measures 1 1/2-inches in depth. It also is one of the oldest operating divisions of Nucor Corporation. Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck. All rights reserved. Vulcraft estimates, details, and custom fabricates steel bar grating in virtually any configuration. NEW! Acoustical versions of this deck (3NLA-32, 3NIA-32, 3PLNA-32, 3NA-24 and 3NIA-24) are available. Copyright VULCRAFT 2023. We offer exceptional product performance and unparalleled support. HIGH PERFORMANCE DECK-SLAB DIAPHRAGM STRENGTH. 0000076803 00000 n The 2VLI and 3VLI profiles are 2-inches deep and 3-inches deep, respectively. 3NP Cellular Deck utilizes the N-Deck profile with 3 deep ribs and a full pan underneath. For more customized design solutions, visit our Online Design Tools. Deck-Slab Diaphragm Strength Whether it is roofing, flooring, or ceilings, Vulcraft provides a variety of steel deck profiles and depths to meet your customers' unique needs. 2.0C Non-Composite Deck measures 2-inches in depth; 3.0C Non-Composite Deck measures 3-inches in depth. 0000059559 00000 n Typically used in non-residential construction, steel joists and joist girders provide an economical system for supporting floors and roofs. Calculate diaphragm strengths and stiffness for deck-slabs with plain concrete, Bekaert Dramix steel fibers, WWR or rebar. 0000075040 00000 n Select a Pour Stop to use as a beam spanning between deck supports per Steel Deck Institute Technical Note No. 0000036547 00000 n By acting as both a ceiling and roof, this versatile product combines the strength of roll formed steel with an aesthetically pleasing bottom plate. Copyright VULCRAFT 2023. Each catalog can be viewed online, downloaded, or ordered. 0000009730 00000 n Vulcraft Literature. Vulcraft Non-Composite Floor Decks are IAPMO (IAPMO UES ER-652) and UL Listed. Founded in 1946, Vulcraft is the largest producer of open web steel joists and joist girders in North America. The Ecospan System is an innovative, simple, effective, and economical method of providing all steel, open web structural components for elevated floor construction. Floor Framing; Truss Framing; Finishing; Component Blocks; . They provide a durable and attractive roof or floor system for fast all-weather construction, and they offer excellent lateral diaphragm action thus reducing the necessity for structural bracing. Vulcrafts grating can be found around the world in industrial sectors such as oil and gas production, mining, water and wastewater treatment, power generation, as well as in a wide variety of architectural applications. By their nature, our metal decking is noncombustible, assuring architects, engineers, and owners excellent fire ratings. 0000078565 00000 n It incorporates the benefit of open web configuration along with 48 to 72 joist spacing. United States:TJ-4015, Spanish:TJ-4015S Black & White:TJ-4015-BW, United States:TJ-4014 Black & White:TJ-4014-BW. Were focused on renewable energy development, forest carbon and CCS, conservation and mitigation banking. 0000022014 00000 n 0000075921 00000 n Curious what depth(s) are most economical for your open-web steel joist system? The tools can be utilized for wide flange and HSS columns. trailer 0000011612 00000 n 0000074678 00000 n Please limit usage to 6 design tools at a given time for maximum performance. See datasheets for specific listings. A variety of side-lap features are also available including interlocked (1.5BP) and PunchLok II connection (1.5PLBP). K-Series: DWG | PDF LH Series: DWG | PDF Joist Girders: DWG | PDF. hb```f``xAb,7 $00 Ix9^{E00iR$ H&p!Kn-6f8gsciXR8!a,$X}Lga`H3]n+V -0_ .Qp L, endstream endobj 3055 0 obj <> endobj 3056 0 obj <. 0000074599 00000 n Second to none in service and backed by the Nucor family of quality companies, Vulcraft is destined to be North Americas best one-source for standard, heavy duty, and custom fabricated grating. Steel Bar Joists and Joist Girders - Software Plugins For CAD Versa-Dek Deep-Dek 1.0 Deck; F Deck; B Deck; NW32 and N Deck; Curve-Dek Architectural Deck. Calculate your maximum unshored span for thick slabs based on your design criteria. Copyright VULCRAFT 2023.All rights reserved. 0000075480 00000 n For more than a hundred years, Weyerhaeuser has been building and enhancing a reputation for responsible corporate citizenship. Copyright VULCRAFT 2023. Founded in 1946, Vulcraft is the largest producer of open web steel joists and joist girders in North America. Online design tools that make it easy to find the right product for your next project. Joist & Joist Girders - Vulcraft 0000045367 00000 n Dovetail Deck profiles create a highly effective and value-added deck type for roof systems. Acoustical version of this deck (1.5BA, 1.5BIA and 1.5PLBA) are available. Vulcraft/Verco Group Metal Decking CAD Details The Vulcraft/Verco Group CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. 1.5BP Cellular Deck (wide rib) deck utilizes the classic 1.5B roof deck with a full pan underneath. 0000010912 00000 n Need help deciding what grating to use? AutoCAD), as page 1 of X. 0000009189 00000 n Our NuBIM for Revit add-in allows users to specify and model all parallel chord joists and joist girders available from Vulcraft as well as a number of common special profile joists, Ecospan and composite joists. High Performance Deck-Slab Diaphragm Strength Calculate diaphragm strengths and stiffness for deck-slabs with plain concrete, Bekaert Dramix steel fibers, WWR or rebar. See datasheets for specific listings. These decks are designed in accordance with the ANSI/Steel Deck Institute C-2017. These profiles are also available with acoustical properties (1.5VLPA,1.5PLVLPA, 2.0VLPA, 2.0PLVLPA, 3.0VLPA and 3.0PLVLPA). Steel decking is used in many applications but is particularly well suited to roofing and flooring. ZipFile.zip Access Free CAD, BIM and Specifications Access Thousands of Free CAD Drawings, BIM Models & Product Specifications Your North American Source for High-Quality Building Product Information All All CAD BIM 3D Specs Products Projects Search PDF Vulcraft - Steel Roof and Floor Deck Vulcraft Cellular Decking is ideal for exposed ceiling areas where a flat bottom ceiling is desired without compromising load capabilities. Nucor | Nucor Steel Joists 0000073282 00000 n Vulcraft/Verco Group CAD Details ARCAT Free Architectural CAD drawings, blocks and details for download in dwg and pdf formats for use with AutoCAD and other 2D and 3D design software. q 2l`[98#(r20_ua;t1AC!c@h}CVg`b&m The following details are examples of common joist bearing conditions. PLW3-36 Formlok is 3" deep and is in stock in galvanized G60. Use SketchUp software to model the structural frame. PDF 1.5B-36/1.5BI-36/1.5PLB-36 ROOF DECKS GRADE 50 STEEL ASD - Vulcraft
- Post category:is abortion pain like labor pain